Feedback for robotic tool changes

Sensor Zero-Point Module

Add sensor feedback to robot tool changes.

Bring feedback from the zero-point interface into the robot's control sequence. Compare three sensor-equipped modules, then match the mechanical interface, stud roles and selectable NPN or PNP output to your controller. Confirm the monitored state and complete handling sequence for the selected installation.

Review My Module InterfaceOpen 2026 product catalog

Work email required to open the catalog

5 kN / 10 kN / 18 kNClamping force. The first figure is the smaller module.
0 - 0.56 mm detection distanceDetection distance on every module.
DC 10 - 30 VSupply voltage for the sensor.
Standard models in stock Custom hole patterns HMC / VMC / 4th / 5th axis Quality documents scoped at RFQ MIC Audited Supplier

Select the mechanical pair and controller connection

Review the model and stud table alongside the sensor interface. The complete installation determines which state is monitored and how the controller uses the feedback.

Compare the three sensor modules

These values are the 2026 NEXTAS quick-change catalogue text for the three named models. They do not replace the approved drawing.

Module & stud selection

Match the module to the C1 positioning, C2 compensating or C3 clamping stud required by the approved assembly drawing. These are locating roles, not an instruction to fit three studs into a single receiver; do not mix part numbers across module rows.

Three sensor modules
ItemClamping forcePositioning studCompensating studClamping studWeight
NT-S200P85V25 kNNT-S200P25C1NT-S200P25C2NT-S200P25C33.4 kg
NT-S200P115V210 kNNT-S200P30C1NT-S200P30C2NT-S200P30C35.4 kg
NT-S200P148V218 kNNT-S200P35C1NT-S200P35C2NT-S200P35C36.9 kg

Mounting dimensions

Match φD1, φD2, H1, H2, M and φS to the same module row, then verify the approved interface drawing before machining or assembly.

Dimensions
ItemφD1φD2H1H2MφS
NT-S200P85V2110 mm85 mm55 mm46 mmM697 mm
NT-S200P115V2140 mm115 mm63 mm51 mmM8131 mm
NT-S200P148V2185 mm148 mm76 mm61 mmM10164 mm

Catalogue interface drawings and NPN/PNP circuit references. Match dimensions, port callouts and wiring to the selected module drawing before installation.

Sensor module side view with D1, D2, H1 and H2 callouts
2026 NEXTAS catalogue · p. 13
Sensor module top view with mounting callouts
2026 NEXTAS catalogue · p. 13

Sensor & electrical parameters

Polarity is NPN or PNP and is selectable. Detection distance is 0 - 0.56 mm. Supply voltage is DC 10 - 30 V. Response frequency is 5 kHz. Current consumption is 10 mA or less. Open and close capacity is an open collector at 50 mA or less. Protective structure is IEC specification IP67.

Exposed cable: robotic folding resistant highly flexible cables. The protection circuit lists power reverse connection protection, surge absorption, load short circuit protection, and output reverse connection protection. IP67 describes the listed protective structure; it is not a machine safety certification.

NPN sensor output circuit
2026 NEXTAS catalogue · p. 13 — NPN
PNP sensor output circuit
2026 NEXTAS catalogue · p. 13 — PNP
M8 sensor connector pin arrangement
2026 NEXTAS catalogue · p. 13 — M8 sensor connector pin arrangement

Selection and mounting

Verify the monitored state and the handling sequence

  • Use the module and stud selection table for the mechanical pairing and the mounting dimensions for the same selected model.
  • Review Sensor & electrical parameters and the NPN/PNP wiring references against the controller input and supply.
  • Confirm what the selected installation monitors, what each signal means, and the complete handling sequence before enabling motion. General sensor feedback does not replace machine safety assessment or validation of interlocks and fault recovery.
  • Confirm repeatability and the unlocking method on the selected module drawing. The weight column is module mass, not a lift-load rating.

Applications

Plan the robot tool-change interface

The catalogue places these modules in the robot-mounted zero-point tool changer series, with a flexible cable intended for repeated robot motion. Manual flat plates are a separate product family; their item numbers do not identify a sensor module.

Connect mechanical and electrical selection

Review module dimensions, matching studs and sensor output together before committing to the layout.

Choose the force class

The three listed modules offer different clamping forces; check the complete load case for selection.

Plan the controller interface

Use the sensor and wiring data to review supply voltage, input type and signal behavior.

Page updated . Catalog values for this family come from the 2026 NEXTAS industry quick-change clamping catalog. Confirm drawing-controlled dimensions on the selected model drawing. Request the catalog. Factory, catalogs, and shows.

Product resources

Frequently Asked Questions

Which sensor modules can I order?

NT-S200P85V2, NT-S200P115V2, and NT-S200P148V2. Match the item number on the drawing to one of these three rows.

What studs does each row name?

The matching table lists positioning, compensating and clamping stud roles for each module. Use the role required by the approved assembly drawing; the three listed part numbers do not mean fitting three studs into one receiver.

Where on the drawing do I confirm repeatability and unlock?

Confirm repeatability and the unlocking method on the drawing of the selected module before you release the job.

What do the electrical figures help me match?

Use the Sensor & electrical parameters to match the controller supply, NPN/PNP input and signal behavior. Confirm the monitored state for the selected installation.

How do I request a quote?

Share the machine interface, module item number if known, and quantity. We will review the matching studs and sensor interface and quote the selected configuration.

Fast quote

Match the module to your robot setup

Send the mounting interface, controller input type and intended handling task. If the module is undecided, we can help shortlist the options and confirm the drawings needed for quotation.

Mounting interface; controller input type if known; handling task. Add a module reference or quantity if available.

Start with the details you have. Include an authorized download link for drawings, or send them by email. Email drawings

Our engineering team will review your details and reply with the next steps.

We use your details to respond to this inquiry. Privacy policy